STANDARD INVERTER DUCTED

STANDARD INVERTER DUCTED

Engineered to deliver a compact and efficient design, our Standard Inverter series is ideal for installation into the tight roof space of any modern home.

  • Available in
    Reverse Cycle (Heating & Cooling)
  • Capacities
    7.1kW, 10.0kW, 12.5kW, 14.0kW, 15.5kW, 18.0kW, 20.0kW, 23.5kW
  • Refrigerant
    R410A

Single Phase Specs



Indoor Unit FDYQN71LBV1 FDYQN100LBV1 FDYQN125LAV1 FDYQN140LBV1 FDYQN160LAV1
Outdoor Unit RZQ71LV1 RZQ100LV1 RZQ125LV1 RZQ140LV1 RZQ160LV1
Rated
Capacity
Cool (kW) 7.1 10.0 12.5 14.0 15.5
  Heat (kW) 7.5 12.5 15.0 16.5 18.0
Capacity
Range
Cool (kW) 3.2-7.1 5.0-10.0 5.7-12.5 6.2-14.0 7.3-15.5
  Heat (kW) 3.5-7.5 5.1-12.5 6.0-15.0 6.2-16.5 7.3-18.0
Power
Input (Rated)
Cool (kW) 2.25 3.12 4.14 4.65 4.97
  Heat (kW) 2.29 3.59 4.48 4.48 4.83
E.E.R/C.O.P C/H 3.15/3.27 3.21/3.48 3.02/3.35 3.01/3.68 3.12/3.73
Airflow
Rate (Rated)
l/s 566 800 840 1000 1120
Indoor
Sound Level (H) @ 1.5m
dBA 41 44 45 48.5 50.5
Piping
Length
m 50 75
Indoor
Fan Speeds
  H/M/L
Dimensions
(HxWxD)
Indoor (mm) 300x1090x863 360x1157x899 360x1498x899
  Outdoor (mm) 770x900x320 990x940x320 1170x900x320 1430x940x320
Weight Indoor (kg) 40 44 61 61 61
  Outdoor (kg) 64 75 98 108 108
Power
Supply 
V/Hz 1 Phase, 220-240V,
50Hz
Compressor
Type
  Hermetically Sealed Swing Type Hermetically Sealed
Scroll Type
Refrigerant   R410A
Pipe
Sizes
Liquid (mm) 9.5 (Flared)
  Gas (mm) 15.9 (Flared)
  Drain (mm) ID 25 / OD 32
Supply
Air Opening 
mm (HxW, Flange) 185×852 245×852 243×1152
Return
Air Opening 
mm  1×400 (Oval) 2×400 (Oval)
Outdoor
Operating Range 
Cool (°CDB) -5 to 46
  Heat (°CWB) -15 to 16
EPA Sound
Power Level 
dBA 66 69
Outdoor
Sound Level (H) @ 1m
Pressure dBA
(C/H)
49/51 51/53 51/53 54/56 57/59

Three Phase Specs



Indoor Unit FDYQN180LBV1 FDYQN200LBV1 FDYQN250LBV1
Outdoor Unit RZQ180LY1 RZQ200LY1 RZQ250LY1
Rated
Capacity
Cool (kW) 18.0 20.0 23.5
  Heat (kW) 20.0 22.4 26.8
Capacity
Range
Cool (kW) 10.8-18.0 12.0-20.0 15.0-23.5
  Heat (kW) 12.0-20.0 13.4-22.4 16.8-26.8
Power
Input (Rated)
Cool (kW) 5.88 6.44 7.85
  Heat (kW) 6.15 7.00 8.47
E.E.R/C.O.P C/H 3.06/3.25 3.11/3.20 2.99/3.16
Airflow
Rate (Rated)
l/s 1180 1200 1400
Indoor
Sound Level (H) @ 1.5m
dBA 45.5 44 49.5
Piping
Length
m 50
Indoor Fan
Speeds
  H/M/L
Dimensions
(HxWxD)
Indoor (mm) 500x1230x970 500x1430x970
  Outdoor (mm) 1680x930x765
Weight Indoor (kg) 78 86 92
  Outdoor (kg) 192 192 193
Power
Supply 
V/Hz 3 Phase, 415v, 50Hz
Compressor
Type
  Hermetically Sealed
Scroll Type
Refrigerant    
Pipe Sizes Liquid (mm) 9.5 (Brazed)
  Gas (mm) 19.1 (Brazed) 22.2 (Brazed)
  Drain (mm) BSP 3/4 inch Internal
Thread
Supply Air
Opening 
mm (HxW, Flange) 376×827 376×938
Return Air
Opening 
mm  350×918 (Flange) 350×1118 (Flange)
Outdoor
Operating Range 
Cool (°CDB) -5 to 43
  Heat (°CWB) -20 to 16
EPA Sound
Power Level 
dBA
Outdoor
Sound Level (H) @ 1m
Pressure dBA
(C/H)
57/57 57/57 57/58

Features

Ultra-Compact

Compact Size

140 and 160 Class is now housed in a compact indoor casing for easier installation.

    Fan Settings

    15 Fan Settings

    15 different fan speed settings to suit your ductwork configuration.

      Improved Energy Efficiency

      Improved Energy Efficiency

      Achieved through the use of a DC Fan motor, cross-pass heat exchanger and increased outdoor coil passes.

      Australian-Made

      Australian Made

      Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.

        Night Quiet Mode

        Night Quiet Mode

        Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.

          Inverter Technology

          Inverter Technology

          An inverter system works like the accelerator of a car, gently increasing or decreasing power. They reach the desired temperature quicker and steadily maintain it without fluctuations.

          Brochure