PREMIUM INVERTER DUCTED

PREMIUM INVERTER DUCTED

Daikin Premium Inverter provides superior comfort in next to no time.

Engineered to deliver remarkable energy performance, design flexibility and R22 retrofit capability, the Premium Inverter Ducted range is perfect for providing discreet air conditioned comfort throughout your entire home.

  • Available in
    Reverse Cycle (Heating & Cooling)
  • Capacities
    5.1kW, 6.0kW, 7.1kW, 10.0kW, 12.5kW, 14.0kW, 16.0kW, 18.0kW, 20.0kW, 24.0kW
  • Refrigerant
    R410A

Single Phase Specs



Indoor Unit FDYQ50DV1 FDYQ60DV1 FDYQ71LBV1 FDYQ100LBV1 FDYQ125LBV1 FDYQ140LCV1 FDYQ160LBV1
Outdoor Unit RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS160AV1
Rated
Capacity
Cool (kW) 5.1 6.0 7.1 10.0 12.5 14.0 16.0
  Heat (kW) 6.0 7.0 7.5 12.5 15.0 16.5 18.0
Capacity
Range
Cool (kW) 3.2-5.6 3.2-6.0 3.2-8.0 5.0-11.2 5.7-14.0 6.2-15.5 7.3-16.3
  Heat (kW) 3.5-7.0 3.5-8.0 3.5-9.0 5.1-12.8 6.0-16.2 6.2-18.0 7.3-18.2
Power
Input (Rated)
Cool (kW) 1.5 1.71 2.05 2.69 3.68 4.13 4.92
  Heat (kW) 1.62 2.09 1.89 3.02 3.79 4.29 4.72
E.E.R/C.O.P C/H 3.40/3.70 3.51/3.35 3.46/3.96 3.72/4.14 3.40/3.96 3.39/3.85 3.25/3.81
Airflow
Rate (Rated)
l/s 370 400 566 800 840 1000 1120
Indoor
Sound Level (H) @ 1.5m
dBA 44.4 45.2 41 44 45.5 46 48
Piping
Length
m 50 75
Indoor
Fan Speeds
  H/M/L
Dimensions
(HxWxD)
Indoor (mm) 300x1015x851 300x1090x863 360x1157x899 360x1400x899 430x1400x943
  Outdoor (mm) 770x900x320 990x940x320 1430x940x320
Weight Indoor (kg) 35 35 40 44 59 62 62
  Outdoor (kg) 64 64 75 108 108 108 108
Power
Supply 
V/Hz 1 Phase, 220-240V,
50Hz
Compressor
Type
  Hermetically Sealed
Swing Type
Hermetically Sealed
Scroll Type
Refrigerant   R410A
Pipe
Sizes
Liquid (mm) 6.4 (Flared) 9.5 (Flared)
  Gas (mm) 12.7 (Flared) 15.9 (Flared)
  Drain (mm) ID 25 / OD 32
Supply
Air Opening 
mm (HxW, Flange) 202×762 185×852 245×852 245×1152 315×1152
Return
Air Opening 
mm 1×400 (Oval) 2×400 (Oval)
Outdoor
Operating Range 
Cool (°CDB) -5 to 46
  Heat (°CWB) -15 to 16
EPA Sound
Power Level 
dBA 66 66 69 69
Outdoor
Sound Level (H) @ 1m
Pressure dBA
(C/H)
48/50 48/50 50/52 53/55 54/56 54/56 57/59

Three Phase Specs



Indoor Unit FDYQ100LBV1 FDYQ125LBV1 FDYQ140LCV1 FDYQ160LBV1 FDYQ180LBV1 FDYQ200LBV1 FDYQ250LAV1
Outdoor Unit RZQS100AY1 RZQS125AY1 RZQS140AY1 RZQS160AY1 RZQS180AY1 RZQS200AY1 RZYQ10PUY1
Rated
Capacity
Cool (kW) 10.0 12.5 14.0 16.0 18.0 20.0 24.0
  Heat (kW) 12.5 15.0 16.5 18.0 20.0 22.4 26.8
Capacity
Range
Cool (kW) 5.0-11.2 5.7-14.0 6.2-15.5 7.3-16.3 10.8-20.0 12.0-22.4 15.0-28.0
  Heat (kW) 5.1-12.8 6.0-16.2 6.2-18.0 7.3-18.2 12.0-22.4 13.4-25.0 16.8-31.5
Power
Input (Rated)
Cool (kW) 2.69 3.68 4.13 4.92 5.64 6.08 7.47
  Heat (kW) 3.02 3.79 4.29 4.72 5.84 6.17 8.14
E.E.R/C.O.P C/H 3.72/4.14 3.40/3.96 3.39/3.85 3.25/3.81 3.19/3.42 3.29/3.63 3.21/3.29
Airflow
Rate (Rated)
l/s 800 840 1000 1120 1180 1200 1400
Indoor
Sound Level (H) @ 1.5m
dBA 44 45.5 46 48 45.5 44 49.5
Piping
Length
m 75 100 150
Indoor Fan
Speeds
  H/M/L
Dimensions
(HxWxD)
Indoor (mm) 360x1157x899 360x1400x899 430x1400x943 500x1230x970 500x1430x970 500x1430x910
  Outdoor (mm) 1430x940x320 1680x930x765 1680x1240x765
Weight Indoor (kg) 44 59 62 62 78 86 92
  Outdoor (kg) 108 108 108 108 192 285
Power
Supply 
V/Hz 3 Phase, 380-415V, 50Hz
Compressor
Type
  Hermetically Sealed
Scroll Type
     
Refrigerant   R410A      
Pipe Sizes Liquid (mm) 9.5 (Flared) 9.5 (Brazed)
  Gas (mm) 15.9 (Flared) 19.1 (Brazed) 22.2 (Brazed)
  Drain (mm) ID 25 / OD 32 BSP 3/4 inch Internal
Thread
Supply Air
Opening 
mm (HxW, Flange) 245×852 245×1152 315×1152 376×827 376×938
Return Air
Opening 
mm 2×400 (Oval) 350×918 (Flange) 350×1118 (Flange)
Outdoor
Operating Range 
Cool (°CDB) -5 to 46 -5 to 43
  Heat (°CWB) -15 to 16 -20 to 16
EPA Sound
Power Level 
dBA 69
Outdoor
Sound Level (H) @ 1m
Pressure dBA
(C/H)
53/55 54/56 54/56 57/59 57/57 57/57 60/60

Features

Australian-Made

Australian Made

Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.

    Night Quiet Mode

    Night Quiet Mode

    Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.

      Wide-Capacity Limit

      Wide Capacity Limit

      Allows continuous operations even on the hottest days of summer, or the coldest days of winter (max ambient temperature in Cooling 46°CDB and Heating -15°CWB).

      R22-Retrofit Capability

      R22 Retrofit Capability

      Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping.

        Inverter Technology

        Inverter Technology

        An inverter system works like the accelerator of a car, gently increasing or decreasing power. They reach the desired temperature quicker and steadily maintain it without fluctuations.

          Industry Leading

          Industry Leading Energy Performance

          Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.

          Brochure

          Download