FLOOR STANDING

FLOOR STANDING

Daikin’s floor standing air conditioning units are compact and ideal for anyone wanting the convenience and access of positioning their unit closer to the floor. They come in a wide selection of capacities and can even be semi-recessed into the wall or in an unused fireplace.

  • Available in
    Reverse Cycle (Heating & Cooling)
  • Capacities
    2.5kW, 3.5kW, 4.5kW, 5.0kW, 6.0kW, 7.1kW
  • Refrigerant
    R410A

Specs



Indoor Unit FVXS25RV1A FVXS35RV1A FVXS45RV1A FVXS50RV1A FVXS60LVMA FVXS71LVMA
Outdoor Unit RXS25RV1A RXS35RV1A RXS45RV1A RXS50RV1A RXS60LAVMA RXS71LAVMA
Rated
Capacity
Cool (kW) 2.46 3.5 4.5 5.0 6.0 7.1
  Heat (kW) 2.9 4.52 5.56 5.8 7.0 7.65
Capacity
Range
Cool (kW) 1.3-3.0 1.7-3.8 1.7-5.0 1.7-5.6 2.3-6.7 3.0-8.5
  Heat (kW) 1.3-4.5 1.7-5.0 1.7-8.1 1.7-8.1 2.3-9.0 3.0-10.0
Indoor
Airflow Rate (H)
Cool (l/s) 137 147 178 260 292 273
  Heat (l/s) 170 170 218 327 285 317
Indoor
Fan Speeds
  5 steps, quiet and
automatic
Energy
Label/Star Ratings
Cool 3.5 3 2 3 2.5 2
  Heat 4.5 3 3 3.5 2 2
Front
Panel Colour
  White
Power
Supply
  1 phase, 220-240V,
50Hz
Power
Input (Rated)
Cool (kW) 0.59 0.91 1.35 1.29 1.7 2.13
  Heat (kW) 0.63 1.16 1.45 1.44 2.03 2.21
E.E.R/C.O.P Cool/Heat 4.17/4.60 3.85/3.90 3.33/3.83 3.88/4.03 3.53/3.45 3.33 / 3.46
A.E.E.R/A.C.O.P Cool/Heat 4.12/4.55 3.82/3.87 3.32/3.82 3.86/4.01 3.51/3.44 3.32/3.45
Dimensions
(HxWxD)
Indoor (mm) 600x700x210 770x850x290
  Outdoor (mm) 550x765x285 735x825x300 770x900x320 990 x 940 x 320
Weight Indoor (kg) 14 14 14 25 25 25
  Outdoor (kg) 34 46 46 46 71 80
Compressor
Type
  Hermetically sealed
swing type
Refrigerant
Type
  R410A
Max Pipe
Length
(m) 20 30 30 30 30 30
Max Level
Difference
(m) 15 20 20 20 20 20
Pipe
Sizes
Liquid (mm) 6.4 6.4 6.4 6.4 6.4 9.5
  Gas (mm) 9.5 12.7 12.7 12.7 12.7 15.9
Outdoor
Operating Range
Cool (°CDB) 10 to 46
  Heat (°CWB) -15 to 18
Indoor
Sound Level (H/SL)
Cool (dBA) 38/23 39/24 44/32 45/32 47/33 46/33
  Heat (dBA) 41/23 41/24 48/32 49/32 45/33 47/34
Outdoor
Sound Level (H/SL)
Cool (dBA) 46/43 47/44 47/44 47/44 49/46 52/49
  Heat (dBA) 50/44 50/45 51/45 51/45 49/46 54/50
Outdoor
EPA Sound Power Level (H)
Cool (dBA) 58 59 59 59 63 66
  Heat (dBA) 62 62 63 63 63 66

Features

Automatic-Operation

Automatic Mode Changeover

Allows the unit to automatically switch between heating and cooling for year round comfort.

    Wide Operating Range

    Wide Operating Range

    Robust design enables the unit to operate from -15°CDB in Heating mode to 46°CWB in Cooling mode.

      Even Air Distribution

      Even Air Distribution

      Either top, or top and bottom discharge vents can utilised to distribute air evenly throughout the room.

      Hot Start

      Hot Start

      Heating operation commences only when the airflow is warm, preventing those unwanted cold draughts.

        Auto-Fan-Speed

        Auto Fan Speed

        An optimal fan speed is automatically selected to suit the set temperature for a more efficient operation.

          Air-Purification

          Air Purification

          Titanium apatite deodorising air purification filter traps microscopic particles, decomposes odours and even deactivates bacteria.

          Brochure